Quadrupole Mass Spectrometer

MAX Series Quadrupole Mass Spectrometer. High resolution and high mass options for a wide range of applications in physics, chemistry and materials research.

The MAX Series quadrupole mass spectrometers are the industry's highest specification instruments for cutting edge research. They are compact, bolt-on quadrupole mass spectrometers with a comprehensive range of application specific configurations for atomic and molecular physics and chemistry experiments including;

Max Series Quadrupole Mass Spectrometer

  • Temperature programmed desorption
  • Static and dynamic SIMS/SNMS
  • Laser molecule interactions
  • Photoionization
  • UHV and XHV Outgassing studies
  • Molecular beam studies
  • Helium scattering
  • Cluster analysis

The MAX Series quadrupole mass spectrometers may be configured with the high performance 9.5mm triple filter quadrupole rod set or the 19mm triple filter quadrupole rod set, delivering far superior sensitivity, abundance sensitivity, transmission and resolution characteristics than the smaller quadrupoe rod sets available from all other manufacturers.

MAX Series Quadrupole Mass Spectrometer Configuration Options:

  • 9.5mm or 19mm high transmission and resolution triple filter quadrupole
  • Mass range options from 60amu to 16,000amu (see tables below)
  • Positive ion and negative ion measurement
  • Appearance potential and electron attachment modes for neutrals and radicals
  • Dual analogue and ion counting detector for highest dynamic range
  • Conversion dynode
  • Pole bias mid-axis potential
  • Einzel lens optics
  • Axial and right angle sampling configurations
  • 1E-16mbar detection capability
  • Tandem source with high transmission energy filter with <0.5eV energy resolution
  • Photoionization cross beam source
  • Enclosed CI source


Max Series Quadrupole Mass Spectrometer Configurations

Mass Range, Sensitivity, Abundance Sensitivity, Resolution, and Transmission are determined by the quadrupole rod size and the RF operating frequency. Our 19mm quadrupole operating at 60amu for example exhibits excellent peak separation and abundance sensitivity and can easily separate helium and deuterium at just 0.025amu apart.

The tables below provides a specification comparison as a guide to choosing the correct performance instrument for your particular application.


MAX Series Triple Filter Quadrupole Mass Spectrometers: 19mm Rod Set

Mass Spectrometer

System

Mass

Range

Relative

Transmission

Resolution

(M/ΔM FWHM)

Sensitivity

(mA/Torr)

MAX-4000HT
4-4,000amu
50%
1500
0.75
MAX-1000
1-1,000amu
50%
1800
1
MAX-500HT
1-500amu
60%
2000
2
MAX-300
1-300amu
60%
2000 2
MAX-120
1-120amu
65%
2500
3
MAX-60
1-60amu
75%
3000
4

MAX Series Triple Filter Quadrupole Mass Spectrometers: 9.5mm Rod Set

Mass Spectrometer

System

Mass

Range

Relative

Transmission

Resolution

(M/ΔM FWHM)

Sensitivity

(mA/Torr)

MAX-16000
20-16,000amu
15%
1000
0.075
MAX-4000
10-4,000amu
20%
1200
0.1
MAX-2000
2-2000amu
25%
1500
0.3
MAX-1200
2-1200amu
25%
1500 0.3
MAX-500
1-500amu
30%
2000
0.4

Please use our contact form for further information.


 